JUMO PROCESStemp modstandstemperaturføler for procesindustrien (også med ATEX-godkendelse) (902820)
- For temperaturer fra -200...+600°C
- Med følerrør i rusffrit stål, Titan, Tantal, Inconel og Hastelloy
- Med 2-leder-transmitter (4...20mA/HART®) i Ex-udførsel leverbar
- II 1/2 GD EEx ia II C T1 ... T6 IP6x T80 ... T400°C1
- II 1/2 GD EEx d II C T1 ... T6 IP6x T80 ... T400°C1
- Med udskiftelig måleindsats (ikke ved Ex-udførsel)
JUMO dTRANS p33 - Pressure transmitter and level measurement probe for application in explosive areas (type 40.4753)
Feature: with ATEX approval
- 250 mbar ... 600 bar relative / absolute
- Insensitive to aggressive gases, vapors and fluids
- Medium temperature: -40... +85°C
- Up to 200°C (SIP and CIP compatible)
- Protection class: IP65
Particularly for the level measurement probe variant (IP 68):
- 250 mbar to 25 bar
- Medium temperature:-40...+70°C
- Sturdy level measurement probe for indoor and outdoor installation
Spændingsforsyning & galaniskadskiller for Ex-transmittere med 2-ledertilslutning, HART-kombatibel (type 40.4757)
Denne spændingsforsyning & galaniskadskiller for Ex-transmittere kan anvendes sammen med følgende JUMO måleinstrumenter
- Type 40.3022: JUMO dTRANS p20 DELTA
- Type 40.3025: JUMO dTRANS p20
- Type 40.4382: JUMO dTRANS p02 DELTA
- Type 40.4385: JUMO dTRANS p02
- Type 40.4753: JUMO dTRANS p33
- Type 95.6550: JUMO dTRANS T01 HART / Ex
JUMO dTRANS P20 DELTA Ex d differenstryktransmitter trykfast kapslet (type 40.3023)
- HART ®-interface
- Eksplosionsbeskyttelse Ex d (ATEX)
- Linearitet 0,07%
- Turn Down 1:200
- Enkel betjening med dreje-/trykknap
- Karakteristisk og indikator for flowmåling indstillelig
- Rustfrit stål
- Setup-program
- LCD display med bargraf
- Skalering med vilkårlige enheder
- Visning af temperaturføler
- Visning af minimum tryk og maksimalt tryk
- Strømgiverfunktion
Intrinsically safe industrial transducers for humidity, temperature and derived variables (90.7025)
For measuring the relative air humidity and temperature (optional)
- Temperature resistant between -40°C and +180°C (depending on the type of probe)
- Pressure resistant up to 100 bar (depending on the type of probe)
- Optional with calculation and output of dew point temperature, absolute humidity and other variables.
- Intelligent interchangeable probes with storage of all calibration coefficients
- Safe operation of the complete device in zones of category "II 1G EEx ia IIC T4" (zone 0), with protection cover also in "II 1D" (zone 20)
- Retraceable to NIST (including certificate)