More than sensors+aut
Søg
JUMO Måle- og Reguleringsteknik A/S

Fabriksvænget 16
4130 Viby SJ, Danmark

Phone: +45 46 19 46 66
Fax: +45 46 19 43 63
e-mail: info.dk(at)jumo(dot)net

JUMO dTRANS pH 02 - Compact multichannel transmitter/controller for pH, redox, ammonia, standard signals, and temperature (202551)
image_202551

  • Display visualization options: large numbers, bar graph or trend display
  • Integrated calibration routines: 1, 2 and 3 points
  • Math and logic module
  • Calibration logbook
  • Integrated washing timer to control the cleaning equipment
  • 12 integrated user languages
  • Setup program features convenient programming and system documentation
  • RS422/RS485 interface (option)
  • PROFIBUS-DP interface (option)
  • Data logger with real-time clock (option)
  • Electrode monitoring can be activated
  • Optional boards can be retrofitted

JUMO dTRANS AS 02 - Compact multichannel transmitter/controller for standard signals, and temperature (202553)
image_202553

  • Display: mg/l, pH, mV, μS/cm
  • Display visualization options: large numbers, bar graph or trend display
  • Integrated 1-point and 2-point calibration routines
  • Math and logic module
  • Calibration logbook
  • Integrated washing timer to control the cleaning equipment
  • 12 integrated user languages
  • Setup program features convenient programming and system documentation
  • RS422/RS485 interface (option)
  • PROFIBUS-DP interface (option)
  • Data logger with real-time clock (option)
  • Optional boards can be retrofitted

JUMO AQUIS 500 pH Transmitter/Controller for pH, ORP, NH3 (ammonia) concentration and temperature (20.2560)
image_202560 UL / CRUUS Prüfzeichen GOST Prüfzeichen

JUMO AQUIS 500 pH Transmitter/Controller for pH, ORP, NH3 (ammonia) concentration and temperature (20.2560)

JUMO ecoTRANS pH 03 - transmitter / switching device for pH / Redox voltage and temperature (202723)
image_202723

  • Can be changed from pH to mV / ORP (Redox voltage)
  • Simple connection of the probes with screw terminals
  • Asymmetric and symmetric connection of the pH electrodes
  • Two electrically isolated analog outputs 0(4)...20 mA / 0(2)...10 V freely
    configurable as current value output for pH, Redox or temperature
  • Switching output: relay changeover contact
  • Monitoring of the medium temperature is possible
  • Simple, guided calibration procedure
  • 3-way isolation (input, output and power supply are electrically isolated from one another)
  • For mounting on DIN rail
  • Calibration timer
  • Supply including calibration certificate

2-wire transmitter for pH / Redox single-rod electrodes (202701)
image_202701

  • Direct connection of pH / Redox single-rod electrodes to the PLC is possible
  • No influence of high resistance on the measuring signal
  • Range: -600...+600 mV, equivalent to 4...20mA
  • Power supply: DC 11.5...30 V, nominal value 24 V DC
  • Different connection versions are possible